Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
Rev. bras. ortop ; 58(5): 790-797, Sept.-Oct. 2023. tab, graf
Article in English | LILACS | ID: biblio-1529943

ABSTRACT

Abstract Objective To validate the low-cost model for arthroscopy training and analyze the acceptance and usefulness of the developed simulator in medical teaching and training. Method Ten medical students, ten third-year orthopedic residents, and ten shoulder surgeons performed predetermined tasks on a shoulder simulator twice. The parameters used were time to complete the tasks, number of looks at the hands, GOALS score (Global Operative Assessment of Laparoscopic Skills) and comparison between groups and within groups. An adapted Likert scale was applied addressing the individuals' impressions about the simulator and its applicability. Results In the intergroup comparison, the shoulder surgeons had better scores and times than the other groups. When the tasks were repeated, the group of surgeons had a 59% improvement in time (p < 0.05), as did the group of medical students. In the GOALS score, shoulder surgeons had consistently better scores than the other groups. And when we evaluated the evolution from the first to the second test, the group of surgeons and the group of academics had a statistically significant improvement (p < 0.05). In terms of lookdowns, there was a decrease in all groups. There was consensus that the simulator is useful in training. Conclusion The simulator developed allowed the differentiation between individuals with different levels of training in arthroscopic surgery. It was accepted by 100% of the participants as a useful tool in arthroscopic shoulder surgical training.


Resumo Objetivo Validar o modelo de baixo custo para treinamento em artroscopia e analisar a aceitação e utilidade do simulador desenvolvido no ensino e treinamento médico. Método Dez acadêmicos do curso de medicina, dez residentes do terceiro ano em ortopedia e dez cirurgiões de ombro realizaram tarefas pré determinadas em um simulador de ombro duas vezes. Os parâmetros utilizados foram o tempo para completar as tarefas, quantidade de olhares para as mãos, escore de GOALS (Global Operative Assessment of Laparoscopic Skills) e comparados entre os grupos e intragrupos. Uma escala de Likert adaptada foi aplicada abordando as impressões dos indivíduos acerca do simulador e de sua aplicabilidade. Resultados Na comparação intergrupos, os cirurgiões de ombro tiveram melhores escores e tempos que os demais grupos. Quando as tarefas foram repetidas, o grupo de cirurgiões, teve uma melhora de 59% no tempo (p < 0,05), assim como no grupo de acadêmicos. No escore de GOALS os cirurgiões de ombro apresentaram escores consistentemente melhores que os demais grupos. E quando avaliamos a evolução do primeiro para o segundo teste, o grupo de cirurgiões e o grupo de acadêmicos tiveram melhora estatisticamente significante (p < 0,05). No quesito de lookdowns houve diminuição em todos os grupos. Houve consenso em que o simulador é útil no treinamento. Conclusão O simulador desenvolvido permitiu a diferenciação entre indivíduos com diferentes níveis de treinamento em cirurgia artroscópica. Foi aceito por 100% dos participantes como uma ferramenta útil no treinamento cirúrgico artroscópico do ombro.


Subject(s)
Arthroscopy , Shoulder/surgery , Teaching , Simulation Training
2.
Rev. bras. ortop ; 57(4): 702-708, Jul.-Aug. 2022. tab, graf
Article in English | LILACS | ID: biblio-1394885

ABSTRACT

Abstract The present study created a cheap (below US$ 100) shoulder arthroscopy training model, affordable for the practical education of medical students and residents. The model was created using a polyvinyl chloride (PVC) knee joint pipe (150 mm in diameter and 90 degrees in inclination) and a synthetic shoulder model. The parts were arranged to simulate a lateral recumbency with the upper limb in traction, which is the frequent positioning during arthroscopies. Colored dots on the glenoid and a partial rotator cuff model on the upper portion of the scapula were placed to assist training. This inexpensive, easy-to-make model for shoulder arthroscopy can aid surgical training.


Resumo O objetivo do presente trabalho é criar um modelo de treinamento em artroscopia de ombro de baixo custo abaixo de 100 dólares, tornando-o acessível à capacitação prática de estudantes de medicina e residentes. O modelo foi criado utilizando um cano de PVC de 150 mm de diâmetro em 90 graus e um modelo de ombro sintético. O posicionamento das peças foi disposto de forma a simular a posição de decúbito lateral com membro superior em tração, frequente nas artroscopias. Para auxiliar no treinamento, foram demarcados pontos coloridos na glenóide e foi confeccionado um modelo de parte do manguito rotador na porção superior da escápula. Foi possível confeccionar um modelo para treinamento de artroscopia do ombro com um valor abaixo de 100 dólares, de fácil manufatura, que pode ser um auxiliar no treinamento de cirurgiões.


Subject(s)
Humans , Arthroscopy , Shoulder/surgery , Low Cost Technology , Education, Medical , Simulation Training
3.
Rev. bras. ortop ; 57(3): 524-528, May-June 2022. graf
Article in English | LILACS | ID: biblio-1388021

ABSTRACT

Abstract The first meniscal suture was performed in 1885 and took about a century to become popular. Currently, all-inside meniscal repair devices are widely used. However, this technique presents the disadvantage of being a method dependent on specific devices, presenting a higher cost than other techniques. This high cost limits the use of such a technique in many locations. The objective of the present technical note is to describe a microinvasive meniscal suture technique as a modification of the all-inside technique, using a disposable 40 x 12 mm procedure needle. The authors believe that the proposed modification to the technique can make it more popular, enabling the use of the microinvasive technique in places with limited resources.


Resumo A primeira sutura meniscal foi realizada em 1885 e levou cerca de um século para tornar-se popular. Atualmente, os dispositivos de reparo meniscal all-inside são amplamente utilizados. Contudo, esta técnica apresenta a desvantagem de ser um método dependente de dispositivos específicos, apresentando um custo superior aos de outras técnicas. Este valor elevado limita o uso de tal técnica em muitos locais. O objetivo da presente nota técnica é descrever uma técnica de sutura meniscal microinvasiva, como uma modificação da técnica all-inside, utilizando uma agulha descartável de procedimento de 40 x 12 mm. Os autores acreditam que a modificação proposta para a técnica pode torná-la mais popular, possibilitando o uso da técnica microinvasiva em locais com recursos limitados.


Subject(s)
Humans , Arthroscopy , Suture Techniques , Minimally Invasive Surgical Procedures , Tibial Meniscus Injuries/surgery
4.
Rev. bras. ortop ; 57(1): 180-184, Jan.-Feb. 2022. graf
Article in English | LILACS | ID: biblio-1365736

ABSTRACT

Abstract Although it is a versatile tendon, only 1% of surgeons choose to use the quadricipital tendon as a graft in anterior cruciate ligament (ACL) reconstruction. The present article aims to describe a quadricipital graft removal technique in which its deepest part is maintained. The technique consists of an approach in which the first incision is made in the medial part of the quadricipital tendon to prevent it from getting too short. This is due to its triangular design. The technique also addresses the depth and identification of the three layers of the quadricipital tendon so that it is possible to preserve its deepest part. This approach aims to preserve the extensor apparatus and to not communicate it with the joint environment, avoiding fluid extravasation both in the trans and postoperative periods.


Resumo Ainda que seja um tendão versátil, apenas 1% dos cirurgiões optam por utilizar o tendão quadricipital como enxerto na reconstrução do ligamento cruzado anterior (LCA). O presente artigo tem o objetivo de descrever uma técnica de retirada do enxerto quadricipital na qual a sua porção mais profunda é mantida. A técnica consiste em uma abordagem na qual a primeira incisão é feita na porção medial do tendão quadricipital para evitar que ele fique muito curto. Isso acontece devido ao seu desenho triangular. A técnica também aborda a profundidade e a identificação das três camadas do tendão quadricipital para que seja possível preservar sua porção mais profunda. Esta conduta tem o objetivo de uma maior preservação do aparelho extensor e de não haver comunicação com o meio articular, evitando extravasamento de líquido tanto no trans- quanto no pós-operatório.


Subject(s)
Humans , Postoperative Period , Anterior Cruciate Ligament , Transplants , Knee
5.
Rev. Col. Bras. Cir ; 48: e202027910, 2021. tab, graf
Article in English | LILACS | ID: biblio-1250704

ABSTRACT

ABSTRACT Objective: to validate a lumbar spine endoscopic flavectomy simulator using the construct method and to assess the acceptability of the simulator in medical education. Methods: thirty medical students and ten video-assisted surgery experienced orthopedists performed an endoscopic flavectomy procedure in the simulator. Time, look-downs, lost instruments, respect for the stipulated edge of the ligamentum flavum, regularity of the incision, GOALS checklist (Global Operative Assessment of Laparoscopic Skills), and responses to the Likert Scale adapted for this study were analyzed. Results: all variables differed between groups. Procedure time was shorter in the physician group (p < 0.001). Look-downs and instrument losses were seven times greater among students than physicians. Half of the students respected the designated incision limits, compared to 80% of the physicians. In the student group, about 30% of the incisions were regular, compared to 100% in the physician group (p < 0.001). The physicians performed better in all GOALS checklist domains. All the physicians and more than 96% of the students considered the activity enjoyable, and approximately 90% believed that the model was realistic and could contribute to medical education. Conclusions: the simulator could differentiate the groups' experience level, indicating construct validity, and both groups reported high acceptability.


RESUMO Objetivo: validar um simulador de flavectomia endoscópica da coluna lombar por meio do método de constructo e, analisar a aceitação do simulador no ensino médico. Métodos: trinta estudantes de medicina e dez ortopedistas com experiência em videocirurgia realizaram um procedimento de flavectomia endoscópica no simulador. Foram analisados tempo, look-downs, perdas de instrumentos, respeito ao limite estipulado no ligamento amarelo, contorno regular do corte, checklist GOALS (Global Operative Assessment of Laparaoscopic Skills) e respostas à Escala de Likert adaptada para este estudo. Resultados: todas as variáveis diferiram entre os grupos. O tempo do procedimento foi menor no grupo dos médicos (p < 0,001). Look-downs e perdas de instrumentos foram sete vezes superiores entre os alunos do que entre os médicos. Metade dos alunos respeitou os limites de incisão designados, em comparação a 80% dos médicos. No grupo dos alunos, cerca de 30% das incisões foram regulares, em comparação a 100% no grupo dos médicos (p < 0,001). Os médicos tiveram melhor desempenho em todos os domínios da checklist GOALS. Todos os médicos e 96% dos alunos consideraram a atividade prazerosa, e cerca de 90% consideraram que o modelo era realista e poderia contribuir para o ensino médico. Conclusões: o simulador foi capaz de diferenciar o nível de experiência dos grupos, indicando a validade do construto, e ambos os grupos relataram alta aceitação.


Subject(s)
Humans , Physicians , Students, Medical , Laparoscopy , Clinical Competence
6.
Coluna/Columna ; 19(3): 223-227, July-Sept. 2020. tab, graf
Article in English | LILACS | ID: biblio-1133578

ABSTRACT

ABSTRACT Objective The objective of the study was the development of a low cost simulator of the endoscopic lumbar spine flavectomy technique for use as a teaching method in order to make endoscopic training more accessible. Methods The study was a descriptive research project conducted at the Orthopedic Skills Laboratory of the Health Sciences Department of the Federal University of Paraná. Easily accessible, low cost materials, such as a commercial-use mannequin, EVA plastic, PVC and copper tubing were used to develop the simulator.. Results At the end of the project, it was possible to build a simulator of the endoscopic lumbar spine flavectomy technique with a budget of approximately 464 BRL, or approximately 140 USD. Conclusions We concluded that it was possible to build an endoscopic lumbar spine flavectomy technique simulator on a budget of less than half a Brazilian minimum monthly wage, which makes training more accessible to academics, residents and surgeons. Level of Evidence V; Expert opinion.


RESUMO Objetivo O objetivo do estudo é o desenvolvimento de um simulador de baixo custo da técnica de flavectomia endoscópica da coluna lombar, para uso como método de ensino, com o propósito de tornar o treinamento endoscópico mais acessível. Métodos Trata-se de um projeto de pesquisa descritivo, desenvolvido no Laboratório de Habilidades em Ortopedia do Setor de Ciências da Saúde da Universidade Federal do Paraná. Para o desenvolvimento do simulador foram utilizados materiais de fácil acesso e baixo custo, como manequim de uso comercial, plástico EVA, canos de PVC e cobre. Resultados Ao fim do projeto, foi possível construir o simulador da técnica de flavectomia endoscópica da coluna lombar com orçamento aproximado de 464 reais, aproximadamente 140 dólares. Conclusões Concluímos que é possível construir um simulador da técnica de flavectomia endoscópica da coluna lombar com orçamento abaixo de meio salário mínimo, o que torna o treinamento mais acessível a acadêmicos, residentes e cirurgiões. Nível de evidência V; Opinião do especialista.


RESUMEN Objetivo El objetivo del estudio es el desarrollo de un simulador de bajo costo de la técnica de flavectomía endoscópica de la columna lumbar para uso como método de enseñanza, con el propósito de hacer que el entrenamiento endoscópico sea más accesible. Métodos Se trata de un proyecto de investigación descriptivo, desarrollado en el Laboratorio de Habilidades en Ortopedia del Sector de Ciencias de la Universidad Federal de Paraná. Para el desarrollo del simulador fueron usados materiales de fácil acceso y bajo costo, como maniquí de uso comercial, plástico EVA, caños de PVC y cobre. Resultados Al fin del proyecto, fue posible construir el simulador de la técnica de flavectomía endoscópica de la columna lumbar con presupuesto aproximado de 464 reales, aproximadamente 140 dólares. Conclusiones Concluimos que es posible construir un simulador de la técnica de flavectomía endoscópica de la coluna lumbar con presupuesto por debajo de medio salario mínimo, lo que hace que el entrenamiento sea más accesible para académicos, residentes y cirujanos. Nivel de evidencia V; Opinión del especialista.


Subject(s)
Humans , Spine , Teaching , Education, Medical , Endoscopy , Simulation Training
7.
Rev. bras. educ. méd ; 44(1): e037, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1092503

ABSTRACT

Abstract: Introduction: The objective of this study is to describe a model of knee arthroscopy simulator that is affordable, low-cost and easily reproducible, aiming to enable the diffusion of more effective active teaching and training methodologies. Methods: For the creation of the arthroscopic camera, an endoscopic camera for mobile phones and computers model SXT-5.0M manufactured by KKMOON were used. The camera was introduced in a metal tube, which was coupled to a set of three 20 mm PVC hydraulic connectors to simulate the handle and sleeve of the arthroscope. The camera has a resolution of 1280 x 720 pixels and is equipped with six built-in white LED lamps, simulating and eliminating the need to use an additional light source. The knee model was developed using a PVC pipe fixed on a wooden support, to which synthetic femur and tibia models were affixed. Four three-centimeter diameter holes, compatible with the standard arthroscopic portals, were made in the body of the PVC pipe. For the menisci, a model was made out of modeling clay (Corfix®), until the anatomical structures were close to the real ones. The model consists of both menisci and the intercondylar eminence, simulating the proximal tibial articular surface. The model made out of modeling clay was the basis for the production of a thin Crystal Polyester Resin mold. Using the resin mold, the meniscal models were made of Silicone Rubber Type II, widely used in industry and crafts. Results: A functional and reproducible simulator was obtained, consisting of a knee model and an arthroscopic camera. The simulator works adequately adapted to a TV, monitor or computer, and allows the simulation of diagnostic procedures, meniscectomy and meniscoplasty. Conclusion: It is possible to develop a knee arthroscopy simulator, with components available in local and electronic commerce, at a cost of approximately R$ 300.


Resumo: Introdução: O objetivo deste trabalho é descrever um modelo de simulador de artroscopia de joelho acessível, de baixo custo e facilmente reprodutível, com o intuito de permitir a difusão de metodologias de ensino ativas e treinamento mais eficazes. Métodos: Para a confecção da câmera artroscópica, foi utilizada uma câmera endoscópica para celulares e computadores modelo SXT-5.0M da fabricante KKMOON. Introduziu-se a câmera em um tubo de metal, o qual foi acoplado a um conjunto de três conectores hidráulicos de PVC de 20 mm para simular a empunhadura e camisa do artroscópio. A câmera tem resolução de 1.280 x 720 pixels e seis lâmpadas brancas de LED embutidas, simulando e dispensando a utilização de uma fonte de luz auxiliar. O modelo de joelho foi confeccionado a partir de um cano de PVC fixado em uma base de madeira, ao qual se acoplou um modelo de fêmur e tíbia sintéticos. No corpo do cano de PVC, foram confeccionadas quatro perfurações de 3 cm de diâmetro, compatíveis com os portais artroscópicos habituais. Para os meniscos, fez-se um modelo em massa de modelar (Corfix®), até que as estruturas anatômicas estivessem próximas do real. O modelo é composto por ambos os meniscos e pela eminência intercondilar, simulando a superfície articular proximal da tíbia. O modelo de massa de modelar foi a base para um molde em resina poliéster cristal fina. Com o molde em resina, os modelos meniscais foram confeccionados com borracha de silicone para moldes do tipo II, amplamente utilizados na indústria e no artesanato. Resultados: Obteve-se um simulador funcional e reprodutível, composto de um modelo de joelho e uma câmera artroscópica. Tal simulador funciona adequadamente adaptado a uma TV, um monitor ou computador e permite a simulação de procedimentos diagnósticos, meniscectomia e meniscoplastia. Conclusão: É possível desenvolver um simulador de artroscopia de joelho, com peças disponíveis em comércio local e eletrônico, por um valor aproximado de R$ 300,00.

8.
Rev. méd. Paraná ; 78(2): 101-112, 2020.
Article in Portuguese | LILACS | ID: biblio-1223506

ABSTRACT

Objetivo: O objetivo deste trabalho é fazer uma revisão bibliográfica sobre a relação do uso do videogame e o desenvolvimento de habilidades cirúrgicas. Material e Método: Foi utilizado a base de dados da MEDLINE e SciELO para pesquisa. Após a leitura completa dos artigos, alguns outros artigos foram buscados pelas referências. Resultados: Na revisão foram encontrados 919 artigos compatíveis com a estratégia de busca. Após a leitura do resumo foram selecionados 34 artigos que tinham alguma relação com videogame e performance em cirurgia. Conclusões: A relação do uso do videogame e o desenvolvimento de habilidades cirúrgicas tem evidências científicas pobres. O uso dos jogos eletrônicos, como aquecimento, para melhorar a eficiência em cirurgia, tem respaldo na literatura.


Purpose: The aim of this study is to review the literature concerning the relationship between videogame training and the development of surgical abilities. Method: The electronic databases of MEDLINE and SciELO were searched for relevant studies. Additional studies were included based on the references of the previous studies. Results: Nine hundred and nineteen studies were found. After reading the abstracts, 34 studies were selected and included in this study. Conclusions: there is little existing evidence relating videogame training and the development of surgical abilities. However, warming up with videogame training seems improve surgical efficiency. It can be concluded that, before the first surgery, warming up with videogame training can be useful to improve surgical efficiency.


Subject(s)
Video Games , Surgery, Computer-Assisted , Simulation Training
9.
Rev. bras. ortop ; 54(6): 697-702, Nov.-Dec. 2019. graf
Article in English | LILACS | ID: biblio-1057951

ABSTRACT

Abstract Objective Comparative biomechanical analysis of tibial fixation strength for ligament reconstruction with interference screw compared with screw post and washer, and compared with the associated fixation of both methods (hybrid fixation). Method A total of 54 specimens were used (porcine tibias and bovine flexor digital tendons), which were divided into three groups with fixation types similar to those used in anterior cruciate ligament (ACL) reconstruction: 1) fixation with interference screw; 2) fixation with screw post and toothed washer over knot and suture strand; and )- fixation with screw post and washer combined with interference screw (hybrid fixation). The analyses were performed through pull-out biomechanical tensile tests to determine the stiffness and load to system failure (yield load). Results The hybrid fixation group presented a significantly higher final stiffness (59.10 ± 3.45 N/mm) in comparison to the other groups (p < 0.05) and a higher yield load (581.34 ± 33.48 N) compared to the interference screw group (p < 0.05). Conclusion Hybrid fixation had biomechanical advantages over the bovine digital flexor graft fixation system in swine tibia during tensile tests.


Resumo Objetivo Análise biomecânica comparativa da resistência da fixação tibial para reconstrução ligamentar com parafuso de interferência, comparada com parafuso do tipo poste com arruela, e com fixação associada entre os métodos (fixação híbrida). Métodos Foram utilizados 54 corpos de prova (tíbia suína e tendão digital bovino), que foram divididos em 3 grupos com tipos de fixação semelhantes àqueles utilizados na reconstrução do ligamento cruzado anterior: 1) fixação com parafuso de interferência; 2) fixação com parafuso do tipo poste com arruela dentada sobre nó e fios de sutura; e 3) fixação com parafuso do tipo poste com arruela combinada com parafuso de interferência (fixação híbrida). Os testes foram realizados por meio de ensaios biomecânicos de tração tipo pull-out para determinação da rigidez e carga para falha (yield load) do sistema. Resultados O grupo com fixação híbrida apresentou maior rigidez final (59,10 ± 3,45 N/mm) do que os demais grupos (p < 0,05), e carga superior para falha (581,34 ± 33,48 N) em relação ao grupo com parafuso de interferência (p < 0,05). Conclusão A fixação híbrida apresentou vantagens biomecânicas com relação ao sistema de fixação do enxerto de flexor digital bovino em tíbia suína durante os ensaios de tração.


Subject(s)
Animals , Swine , Tendons , Tibia , Traction , Cattle , Anterior Cruciate Ligament , Surgical Fixation Devices , Anterior Cruciate Ligament Reconstruction , Ligaments
10.
Rev. bras. ortop ; 54(6): 665-672, Nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1057956

ABSTRACT

Abstract Objective To develop a predictive model of early postoperative morbidity and mortality with the purpose of assisting in the selection of the candidates for spinal metastasis surgery. Methods A retrospective analysis of consecutive patients operated for metastatic spinal disease. The possible prognostic preoperative characteristics were gender, age, comorbidities, tumor growth rate, and leukocyte and lymphocyte count in the peripheral blood. The postoperative outcomes were 30-day mortality, 90-day mortality and presence of complications. A predictive model was developed based on factors independently associated with these three outcomes. The final model was then tested for the tendency to predict adverse events, discrimination capacity and calibration. Results A total of 205 patients were surgically treated between 2002 and 2015. The rates of the 30-day mortality, 90-day mortality and presence of complications were of 17%, 42% and 31% respectively. The factors independently associated with these three outcomes, which constituted the predictive model, were presence of comorbidities, no slow-growing primary tumor, and lymphocyte count below 1,000 cells/µL. Exposure to none, one, two or three factors was the criterion for the definition of the following categories of the predictive model: low, moderate, high and extreme risk respectively. Comparing the risk categories, there was a progressive increase in the occurrence of outcomes, following a linear trend. The discrimination capacity was of 72%, 73% and 70% for 30-day mortality, 90-day mortality and complications respectively. No lack of calibration occurred. Conclusion The predictive model estimates morbidity and mortality after spinal metastasis surgery and hierarchizes risks as low, moderate, high and extreme.


Resumo Objetivo Desenvolver um modelo preditivo de morbimortalidade pós-operatória precoce com o intuito de auxiliar na seleção dos candidatos à cirurgia para metástase vertebral. Métodos Análise retrospectiva de pacientes consecutivos operados por doença metastática vertebral. As características pré-operatórias consideradas possivelmente prognósticas foram: sexo, idade, comorbidades, velocidade de progressão tumoral e contagem de leucócitos e linfócitos no sangue periférico. Os desfechos pós-operatórios analisados foram: mortalidade em 30 dias e em 90 dias, e presença de complicações. Um modelo preditivo foi desenvolvido a partir de fatores independentemente associados a esses três desfechos. Testou-se então o modelo estabelecido quanto à tendência de prever eventos adversos, à capacidade de discriminação e à calibração. Resultados Um total de 205 pacientes foram operados entre 2002 e 2015. A mortalidade em 30 dias e em 90 dias e a incidência de complicações foram de 17%, 42% e 31%, respectivamente. Os fatores independentemente associados a esses três desfechos, e que constituíram o modelo preditivo, foram: presença de comorbidades, tumor primário de progressão não lenta, e linfócitos abaixo de 1.000 células/µL. A exposição a nenhum, um, dois ou três fatores definiu as categorias do modelo preditivo: baixo, moderado, alto e de extremo risco, respectivamente. Comparando-se as categorias, houve aumento progressivo na ocorrência dos desfechos, seguindo tendência linear. A capacidade de discriminação foi de 72%, 73% e 70% para mortalidade em 30 dias, em 90 dias e incidência de complicações, respectivamente. Não ocorreu falta de calibração. Conclusão O modelo preditivo permite estimar a morbimortalidade após a cirurgia para metástase vertebral e hierarquizar os riscos em baixo, moderado, alto e extremo.


Subject(s)
Humans , Male , Female , Postoperative Complications , Spinal Diseases , Spine/surgery , Lymphocytes , Comorbidity , Indicators of Morbidity and Mortality , Morbidity , Mortality , Lymphocyte Count , Neoplasm Metastasis
11.
Rev. bras. ortop ; 53(5): 564-569, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-977875

ABSTRACT

ABSTRACT Objective: The aim of the study was to compare the mechanical behavior of interference screw tibial fixation vs. screw-plus-staple tibial fixation in an animal model. Methods: Thirty-six pieces of swine knee specimens were selected and divided into two groups: Group 1, tibial fixation with interference screw (n = 17), and Group 2, fixation with interference screw and staple (n = 19). The models were submitted to a single cycle of tension testing. The following variables were measured: graft cross-sectional area, failure point on 10 mm (F10), yield load (Fy), and stiffness. Results: The mean values of graft cross-sectional area, F10, Fy, and stiffness did not present significant differences between the groups. Conclusion: The addition of a second staple-type ligament fixation device, complementing the interference screw, did not increase the mechanical safety of the system.


RESUMO Objetivo: Comparar o comportamento mecânico da fixação tibial com parafuso de interferência versus parafuso de interferência com agrafe, em modelo animal. Métodos: Foram selecionadas 36 peças de joelho suíno e divididas em dois grupos: Grupo 1, fixação tibial com parafuso de interferência (n = 17) e Grupo 2, fixação com parafuso de interferência e agrafe (n = 19). Os modelos foram submetidos a teste de ciclo único de tração. Foram mensuradas as seguintes variáveis: medida da área de seção transversal do enxerto, ponto de falha nos 10 mm (F10), yield load (Fy) e rigidez. Resultados: Os valores médios de área de seção transversal do enxerto, F10, Fy, e rigidez não apresentaram diferenças significativas entre os grupos. Conclusão: A adição de um segundo dispositivo de fixação ligamentar tibial tipo agrafe, complementar ao parafuso de interferência, não aumentou a segurança mecânica do sistema.


Subject(s)
Animals , Orthopedic Fixation Devices , Tendons , Tibia , Biomechanical Phenomena , Anterior Cruciate Ligament
12.
ABCD (São Paulo, Impr.) ; 29(supl.1): 75-79, 2016. tab, graf
Article in English | LILACS-Express | LILACS | ID: lil-795055

ABSTRACT

ABSTRACT Background: Obesity is a chronic disease and has become the most prevalent public health problem worldwide. The impact of obesity on knee is strong and the BMI is correlated with the different alterations. Aim: Compare surgical visualization of arthroscopic field in partial meniscectomy in obese and non-obese. Method: Sixty patients were selected, 30 obese and 30 non-obese who underwent arthroscopic partial meniscectomy. The arthroscopic surgical procedures were recorded and analyzed. For the analysis of visualization was used the Johnson's classification (2000). Results: Were analyzed 48 men and 12 women, the average age was 42.9 years with BMI between 21.56 to 40.14 kg/m2. The distribution of visibility of the surgical field according to the classification was: grade 1 - 38/60 (63.3%); grade 2 - 13/60 (21.6%); grade 3 - 6/60 (10%); grade 4 - 3/60 (5%). Conclusion: Knee arthroscopy did not show a significant difference in the visibility of arthroscopic field in obese and non-obese patients. Thus, it should not be indicated as the preferred method of diagnostic evaluation of joint changes in these patients.


RESUMO Racional: A obesidade é doença crônica e tem se tornado o problema de saúde pública mais prevalente em todo mundo. O impacto dela no joelho é grande e o IMC está correlacionado com as diferentes alterações existentes. Objetivo: Comparar a visualização do campo videoartroscópico na meniscectomia parcial de joelho em pacientes obesos e não obesos. Método: Foram selecionados 60 pacientes, sendo 30 obesos e 30 não obesos que realizaram meniscectomia parcial videoartroscópica. Os procedimentos videoartroscópicos foram gravados e posteriormente analisados. Foi utilizada na análise a classificação de visibilidade do campo videoartroscópico de Johnson (2000). Resultados: Foram analisados 48 homens e 12 mulheres com idade média de 42,9 anos e IMC de 21,56 a 40,14 kg/m2. A distribuição da visibilidade do campo cirúrgico foi: grau 1 - 38/60 (63,3%); grau 2 - 13/60 (21,6%); grau 3 - 6/60 (10%); grau 4 - 3/60 (5%). Conclusão: A artroscopia de joelho não demonstrou diferença significativa quanto à visualização do campo videoartroscópico em pacientes obesos e não obesos. Desta forma, não deve ser indicada como método preferencial de avaliação diagnóstica das alterações articulares nesses pacientes.

13.
Rev. bras. ortop ; 50(2): 131-135, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-748349

ABSTRACT

The aim of this study was to review all cases of pseudoaneurysm in the literature, in predominantly arthroscopic procedures on the knee, and to report on a case of pseudoaneurysm that we treated. A bibliographic search was conducted for scientific articles published in Brazilian and foreign periodicals over the last 23 years. Forty-seven cases were found, in 40 articles. In addition to these 47 cases, there was the case that we treated, which was also included in the data. Among the operations that progressed with formation of a pseudoaneurysm, 60% were cases of meniscal injuries and 23%, anterior cruciate ligament injuries. In 46% of the cases, the artery affected with the popliteal, and in 21%, the inferomedial genicular artery. The commonest clinical symptom was pain (37%), followed by pulsating tumor (31%), edema of the calf (12%) and hemarthrosis (11%). The median time taken to make the diagnosis was 11 days, but it ranged from one day to 10 weeks after the procedure. Although rare, pseudoaneurysms are a risk that is inherent to arthroscopic surgery. All patients should be made aware of the vascular risks, even in small-scale procedures.


O objetivo deste estudo é revisar na literatura todos os casos de pseudoaneurisma em procedimentos predominantemente artroscópicos do joelho e relatar um caso de pseudoaneurisma tratado pelos autores. Foi feita uma pesquisa bibliográfica por meio de artigos científicos publicados em periódicos nacionais e internacionais nos últimos 23 anos. Foram levantados 47 casos, em 40 artigos. Somou-se aos 47 um caso dos autores deste estudo que foi incluído nos dados. Das cirurgias que cursaram com pseudoaneurisma, 60% se tratavam de lesões meniscais e 23% de lesões do ligamento cruzado anterior. Em 46% dos casos a artéria acometida foi poplítea e em 21% a artéria genicular inferomedial. O sintoma clínico mais comum foi dor (37%), seguido de tumor pulsátil (31%), edema de panturrilha (12%) e hemartrose (11%). A mediana do tempo para diagnóstico foi de 11 dias, mas variou de um dia até 10 semanas após o procedimento. Apesar de raro, o pseudoaneurisma é um risco inerente à cirurgia artroscópica. Todo paciente deve ser notificado dos riscos vasculares, mesmo em procedimentos de pequeno porte.


O objetivo deste estudo é revisar na literatura todos os casos de pseudoaneurisma em procedimentos predominantemente artroscópicos do joelho e relatar um caso de pseudoaneurisma tratado pelos autores. Foi feita uma pesquisa bibliográfica por meio de artigos científicos publicados em periódicos nacionais e internacionais nos últimos 23 anos. Foram levantados 47 casos, em 40 artigos. Somou-se aos 47 um caso dos autores deste estudo que foi incluído nos dados. Das cirurgias que cursaram com pseudoaneurisma, 60% se tratavam de lesões meniscais e 23% de lesões do ligamento cruzado anterior. Em 46% dos casos a artéria acometida foi poplítea e em 21% a artéria genicular inferomedial. O sintoma clínico mais comum foi dor (37%), seguido de tumor pulsátil (31%), edema de panturrilha (12%) e hemartrose (11%). A mediana do tempo para diagnóstico foi de 11 dias, mas variou de um dia até 10 semanas após o procedimento. Apesar de raro, o pseudoaneurisma é um risco inerente à cirurgia artroscópica. Todo paciente deve ser notificado dos riscos vasculares, mesmo em procedimentos de pequeno porte.


Subject(s)
Humans , Male , Young Adult , Aneurysm, False , Anterior Cruciate Ligament , Arteries , Arthroscopy , Knee
14.
Rev. bras. ortop ; 50(2): 174-179, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-748357

ABSTRACT

OBJECTIVE: To verify whether the combination of tibial cross pin fixation and femoral screw fixation presents biomechanical advantages when compared to femoral cross pin fixation and tibial screw fixation for the reconstruction of the anterior cruciate ligament (ACL). METHODS: Thirty-eight porcine knees and bovine extensor digitorum tendons were used as the graft materials. The tests were performed in three groups: (1) standard, used fourteen knees, and the grafts were fixated with the combination of femoral cross pin and a tibial screw; (2) inverted, used fourteen knees with an inverted combination of tibial cross pin and a femoral screw; (3) control, ten control tests performed with intact ACL. After the grafts fixation, all the knees were subjected to tensile testing to determine yield strength and ultimate strength. RESULTS: There was no statistically significant difference in survival techniques in regard to strength, yield load and tension. There was a higher survival compared in the standard curves of yield stress (p < 0.05). CONCLUSION: There is no biomechanical advantage, observed in animal models testing, in the combination of tibial cross pin fixation and femoral screw when compared to femoral cross pin fixation and tibial screw.


OBJETIVO: investigar se a fixação transversa tibial com parafuso femoral apresenta vantagens biomecânicas sobre a fixação transversa femoral com parafuso tibial na reconstrução do ligamento cruzado anterior (LCA). MÉTODO: foram usados como modelos de testes joelhos suínos e tendões extensores digitais bovinos. Foram submetidos à reconstrução do LCA 28 joelhos: 14 foram fixados com parafuso na tíbia e implante transverso no fêmur (grupo padrão) e 14 com parafuso no fêmur e fixação transversa na tíbia (grupo invertido). Os modelos foram submetidos aos testes de tração. RESULTADOS: não houve diferença estatisticamente significante na sobrevivência das técnicas no que tange a força, força máxima sem falha e tensão. Houve uma sobrevivência maior no grupo padrão na comparação das curvas de tensão de limite elástico (p < 0,05). CONCLUSÃO: não há vantagem biomecânica da fixação transversa tibial com parafuso femoral em relação à fixação transversa femoral com parafuso tibial, observada em testes com modelos animais.


Subject(s)
Animals , Anterior Cruciate Ligament , Femur , Mechanics , Orthopedic Fixation Devices , Tendons , Cattle , Swine
15.
Rev. bras. ortop ; 49(5): 494-498, Sep-Oct/2014. tab, graf
Article in English | LILACS | ID: lil-727690

ABSTRACT

Objective: To study the anatomy of the posterior cruciate ligament (PCL) and define anatomical parameters with the knee flexed at 90°. Methods: Eight knees from cadavers were dissected in order to make measurements from the center of the anterolateral band to the roof (AL1), from the center of the anterolateral band to the anterior cartilage (AL2), from the center of the posteromedial band to the roof (PM1), from the center of the posteromedial band to the anterior cartilage (PM2), from the center of the tibial insertion to the medial region of the tibia (TIM), from the center of the tibial insertion to the lateral region of the tibia (TIL), from the center of the medial insertion to the medial meniscus (IMM) and the width of the origin of the PCL (WO). To obtain the results from each anatomical structure, the means and standard deviations of the measurements were calculated. Results: The measurements in millimeters that were found were AL1, 6.2; AL2, 4.9; PM1, 11.7; PM2, 5.5; TIM, 32.5; TIL, 40.6; IMM, 9.4; and WO, 32.5. Conclusions: The PCL has an extensive origin. The center of the anterolateral band is 6 mm from the roof and 5 mm from the anterior cartilage of the knee. The tibial insertion is slightly medial and 10 mm distal to the posterior cornu of the medial meniscus...


Objetivo: Estudar a anatomia do ligamento cruzado posterior (LCP) e definir parâmetros anatômicos com o joelho em 90° de flexão. Métodos: Oito joelhos de cadáveres foram dissecados para tirar as medidas do centro da banda anterolateral ao teto (AL1), do centro da banda anterolateral à cartilagem anterior (AL2), do centro da banda posteromedial ao teto (PM1), do centro da banda posteromedial à cartilagem anterior (PM2), do centro da inserção tibial à região medial da tíbia (ITM), do centro da inserção tibial à região lateral da tíbia (ITL), do centro da inserção medial ao menisco medial (IMM) e da largura da origem do LCP (LO). Para a obtenção dos resultados de cada estrutura anatômica foram calculados os valores de média e desvio padrão das medições. Resultados: As medidas, em milímetros, encontradas foram AL1, 6,2; AL2, 4,9; PM1, 11,7; PM2, 5,5; ITM, 32,5; ITL, 40,6; IMM, 9,4; e LO, 32,5. Conclusões: o LCP tem uma origem extensa. O centro da banda anterolateral fica a 6 mm do teto e a 5 mm da cartilagem anterior do joelho. A inserção tibial fica levemente medial e 10 mm distal ao corno posterior do menisco medial...


Subject(s)
Humans , Anatomy , Cadaver , Posterior Cruciate Ligament/anatomy & histology
16.
Rev. bras. ortop ; 48(5): 417-420, Sept-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-697312

ABSTRACT

OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT), tibial plateau (TP) and tibial tuberosity (TT). A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the medial border of the patellar tendon and tibial tuberosity to the insertion of the flexor tendons of the knee. The angle between tibial plateau and the insertion of the flexor tendons of the knee (A-TP-FT) was calculated using Image Pro Plus software. RESULTS: The mean distance TP-FT was 41 ± 4.6 mm. The distance between the TT-FT was 6.88 ± 1 mm. The (A-TP-FT) was 20.3 ± 4.9°. CONCLUSION: In the anterior tibial flexor tendons are about 40 mm from the plateau with an average of 20°. .


OBJETIVO: Determinar parâmetros anatômicos para localizar a inserção dos tendões flexores do joelho na tíbia. MÉTODOS: Foram selecionados 10 joelhos de cadáveres com estruturas mediais e anteriores íntegras. A dissecção foi feita por acesso ânteromedial até a exposição adequada da inserção dos tendões flexores (TF), do planalto tibial (PT) e da tuberosidade anterior da tíbia (TAT). Uma agulha 40×12 e um paquímetro digital foram usados para aferir a distância do planalto tibial da inserção dos tendões flexores do joelho a 15 mm da borda medial ao tendão patelar e da tuberosidade anterior da tíbia à inserção dos tendões flexores do joelho. O ângulo o planalto tibial e a inserção dos tendões flexores do joelho (PT-TF) foi calculado com o auxílio do software ImagePro Plus(r). RESULTADOS: A distância PT-TF foi de 41 ± 4,6 mm em média. A distância entre a TAT-TF foi de 6,88 ± 1 mm. A angulação (PT-TF) foi de 20,3 ± 4,9 graus. CONCLUSÃO: Na região anterior da tíbia os tendões flexores estão a cerca de 40 mm do planalto com um ângulo médio de 20 graus. .


Subject(s)
Humans , Anatomy , Cadaver , Knee/anatomy & histology
17.
Rev. bras. ortop ; 48(5): 402-405, Sept-Oct/2013. tab, graf
Article in English | LILACS | ID: lil-697320

ABSTRACT

OBJECTIVE: To study the anatomy of the oblique popliteal ligament, as regards its dimensions, expansion and anatomical relationships. METHODS: Eleven cadaver knees were dissected in order to study the anatomy and take mea-surements of anatomical structures and relationships of the oblique popliteal ligament. The dissection was for posterior access to the proper exposure of the oblique popliteal ligament, the semimembranosus muscle and its expansions. For measurement of dimensions, 40 × 12 needles were used for marking the specific points and a caliper. The angles were calculated using the software ImagePro Plus(r) . RESULTS: The distance from the origin of the oblique popliteal ligament to the tibial plateau was 7.4 mm, the thickness at its origin was 7.3 mm, length was 33.6 mm and the tibial plateau angle 34.8°. The length of the expansion of the proximal oblique popliteal ligament was 39.2 mm, thickness 7.8 mm and angle of the oblique popliteal ligament with its expansion 32.2°. CONCLUSION: The oblique popliteal ligament is thick, rises in the semimembranosus and protrudes proximally forming an acute angle with the joint interline, crossing the popliteal fossa. In some cases it has a proximal expansion. .


OBJETIVO: Estudar a anatomia do ligamento poplíteo oblíquo no que se refere às suas dimensões, expansões e relações anatômicas. MÉTODOS: Onze joelhos de cadáveres foram dissecados com o intuito de se estudar a anatomia e fazer medições das estruturas e das relações anatômicas do ligamento poplíteo oblíquo. A dissecção foi por acesso posterior até a exposição adequada do ligamento poplíteo oblíquo, do músculo semimembranoso e de suas expansões. Para aferição das medidas, foram usados agulhas 40x12 na marcação dos pontos específicos e um paquímetro. Os ângulos foram calculados com o auxílio do software ImagePro Plus(r). RESULTADOS: A distância da origem do ligamento poplíteo oblíquo ao platô tibial foi de 7,4 mm, a espessura na sua origem foi de 7,3 mm, o comprimento foi de 33,6 mm e o ângulo com o platô tibial foi de 34,8°. O comprimento da expansão proximal do ligamento poplíteo oblíquo foi de 39,2 mm, a espessura foi de 7,8 mm e o ângulo do ligamento poplíteo oblíquo com sua expansão foi de 32,2°. CONCLUSÃO: O ligamento poplíteo oblíquo é espesso, nasce no músculo semimembranoso, projeta-se proximalmente, forma um ângulo agudo com a interlinha articular e cruza a fossa poplítea. Em alguns casos apresenta uma expansão proximal. .


Subject(s)
Anatomy , Cadaver , Knee
18.
Acta cir. bras ; 27(5): 283-288, May 2012. ilus, tab
Article in English | LILACS | ID: lil-626240

ABSTRACT

PURPOSE: To determine whether it is possible and the difficulty of anatomical placement of guide wires for reconstruction of the two bands of the anterior cruciate ligament using transtibial technique and to measure the angle and positioning of the anatomic tibial guide wires for this technique. METHODS: Ten cadaver knees were dissected and a guide wire was positioned in the center of origin and insertion of each band. Were collected measurements of the distance from: 1) the entry point of the guide wire on tibial tuberosity; 2) the medial end of the tibia; 3) the tibial articular surface. Were also measured the medial and caudal angles of the guide wires. RESULTS: For the anteromedial band the medial angle was 19±5º and the caudal was 44±4º.The distances were 20±2 mm from anterior tuberosity, 26±5 mm from the tibial plateau and 25±5 mm from the medial end of the tibia. For the posterolateral band the medial angle was 26±5º and the caudal one was 36±8°. The distances were 31±6 mm for the anterior tuberosity, 24±4 mm for the tibial plateau and 17±7 mm from the end of the tibia. CONCLUSIONS: It is possible to position the guide wires of the two bands to reconstruct the anterior cruciate ligament using transtibial technique. The parameters for the proper positioning of the guide wire from anteromedial band is caudal angle of 44º with entry point 20 mm from anterior tuberosity; for the posterolateral band the caudal angle is 36º; from the tibial tuberosity the distance is 31 mm. This technique is difficult to perform leaving its questionable reproducibility.


OBJETIVOS: Determinar se é possível o posicionamento anatômico dos fios-guia para reconstrução das duas bandas do ligamento cruzado anterior pela técnica transtibial, sua dificuldade técnica e medir o posicionamento angular dos parâmetros anatômicos dos fios-guia tibiais para esta técnica. MÉTODOS: Dez joelhos de cadáveres foram dissecados e um fio guia foi posicionado no centro da origem e inserção de cada banda. Foram coletadas as medidas da distância do ponto de entrada do fio-guia à tuberosidade anterior da tíbia, a extremidade medial da tíbia e a superfície articular tibial. Também foram medidos os ângulos mediais e caudais dos fios-guia. RESULTADOS: Para a banda anteromedial o ângulo medial foi de 19±5º e o caudal de 44±4º. As distâncias foram de 20±2 mm da tuberosidade anterior, 26±5 mm do platô tibial e 25±5 mm da extremidade medial da tíbia. Para a banda posterolateral o ângulo medial foi de 26±5° e o caudal de 36±8°. As distâncias foram de 31±6 mm da tuberosidade anterior, 24±4 mm do platô tibial e 17±7 mm da extremidade medial da tíbia. CONCLUSÕES: É possível posicionar os fios-guia para reconstrução das duas bandas do ligamento cruzado anterior pela técnica transtibial. Os parâmetros para o posicionamento adequado do fio-guia da banda anteromedial são ângulo caudal de 44° com ponto de entrada a 20 mm da tuberosidade anterior; para a banda posterolateral o ângulo caudal é de 36° e a distância é de 31 mm da tuberosidade anterior da tíbia. Essa técnica é de difícil execução deixando sua reprodutibilidade questionável.


Subject(s)
Humans , Anterior Cruciate Ligament Reconstruction/methods , Anterior Cruciate Ligament Reconstruction/instrumentation , Cadaver
19.
Rev. bras. ortop ; 47(1): 43-49, jan.-fev. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-624804

ABSTRACT

OBJETIVO: Determinar a resistência inicial de fixação do sistema RigidFix® e comparar com o método tradicional de fixação que utiliza parafusos de interferência metálicos. Avaliar a resistência da fixação com o sistema RigidFix® ao se modificar o posicionamento rotacional do bloco ósseo no interior do túnel femoral. MÉTODOS: 40 espécimes de joelhos (soldras) de ovinos, foram submetidos à reconstrução do ligamento cruzado anterior (LCA)utilizando enxerto osso-tendão-osso. Em 20 espécimes utilizou-se o método RigidFix®, este grupo foi subdividido em dois, 10 joelhos foram utilizados para fixação através da esponjosa e 10 para fixação cruzando a tábua óssea cortical. Nos 20 espécimes restantes fixou-se o enxerto com parafusos de interferência metálico de 9mm. RESULTADOS: A comparação do método RigidFix® com o método de fixação com parafuso de interferência metálico não mostrou diferenças estatisticamente significativas ao se considerar carga máxima e rigidez, também não houve diferenças estatisticamente significativas ao se modificar o posicionamento rotacional do bloco ósseo no interior do túnel femoral. Para estas avaliações considerou-se o p < 0,017. CONCLUSÃO: A fixação do enxerto osso-tendão-osso com dois pinos bioabsorvíveis, independente do posicionamento rotacional no túnel femoral, permite uma fixação comparável em termos de resistência inicial ao parafuso de interferência metálico neste modelo experimental.


OBJECTIVE: to determine the initial resistance of fixation using the Rigid Fix® system, and compare it with traditional fixation methods using metal interference screws; and to evaluate the resistance of the fixation with the rigid fix system when the rotational position of the bone block is altered in the interior of the femoral tunnel. METHODS: forty ovine knee specimens (stifle joints) were submitted to anterior cruciate ligament reconstruction (ACL) using a bone-tendon-bone graft. In twenty specimens, the RigidFix® method was used; this group was subdivided into two groups: ten knees used for fixation with trabecular bone screw, and ten for fixation passing through the layer of cortical bone. In the twenty remaining specimens, the graft was fixed with 9mm metal interference screws. RESULTS: comparison of the Rigidfix® method with the metal interference screw fixation method did not show any statistically significant differences in terms of maximum load and rigidity; also, there were no statistically significant differences when the rotational position of the bone block was altered inside the femoral tunnel. For these evaluations, a level of significance of p < 0.017 was considered. CONCLUSION: fixation of the bone-tendon-bone graft with 2 bioabsorbable pines, regardless of the rotational position inside the femoral tunnel, gave a comparable fixation in terms of initial resistance to the metal interference screw, in this experimental model.


Subject(s)
Animals , Anterior Cruciate Ligament , Bone Transplantation , Bone-Patellar Tendon-Bone Grafting , Knee , Sheep
20.
Rev. Col. Bras. Cir ; 38(5): 338-342, set.-out. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-606822

ABSTRACT

OBJETIVO: Avaliar anatomicamente a origem femoral e inserção tibial das bandas ântero-medial e póstero-lateral do ligamento cruzado anterior. MÉTODOS: Estudados oito joelhos de cadáveres, foram feitas as seguintes medidas no fêmur: distância do centro da banda ântero-medial à cartilagem profunda e a ao teto. Ainda no fêmur, do centro da banda póstero-lateral à cartilagem profunda, a cartilagem inferior e à cartilagem superficial. Na tíbia, foi aferido do bordo ósseo tibial anterior à região anterior da banda ântero-medial, ao centro da banda ântero-medial e ao centro da banda póstero-lateral. Também foi medido o centro da banda póstero-lateral ao bordo ósseo posterior da tíbia e o comprimento ântero-posterior total da inserção tibial do ligamento cruzado anterior. RESULTADOS: No fêmur, a distância do centro da banda ântero-medial à cartilagem profunda foi de 6,3 ±1,4mm e ao teto 11,2 ±2mm. Ainda no fêmur, a medida do centro da banda póstero-lateral à cartilagem profunda 9 ±4mm, à cartilagem superficial 7,6 ±1,8mm e a cartilagem inferior 4,2 ±0,9mm. Na tíbia, a distância do bordo ósseo tibial anterior à região anterior da banda ântero-medial foi de 11,9 ±2,8mm, ao centro da banda ântero-medial 18,8 ±2,6mm e ao centro da banda póstero-lateral 26,5 ±2,3mm. A medida do centro da banda póstero-lateral ao bordo ósseo posterior da tíbia foi 19,6 ±4mm e o comprimento ântero-posterior total da inserção tibial do ligamento cruzado anterior 19,4 ±1,8mm. CONCLUSÃO: O centro da inserção tibial da banda ântero-medial encontra-se a aproximadamente 20mm da extremidade anterior da tíbia, enquanto o centro da póstero-lateral se encontra a 30mm. A distância entre o centro da origem da banda ântero-medial até a cartilagem profunda é 6mm e da póstero-lateral 10mm.


OBJECTIVE: To anatomically evaluate the femoral origin and tibial insertion of the anteromedial and posterolateral bands of the anterior cruciate ligament. METHODS: We studied eight cadaver knees as for the following: in the femur, distance from the center of the anteromedial band to the deep cartilage and the ceiling; also in the femur, distance from the center of the posterolateral band to the deep cartilage, to the inferior cartilage and to the superficial cartilage. In the tibia, we measured the distances between the anterior tibial bone edge to the anterior region of the anteromedial band, to the center of the anteromedial band and to the center of the posterolateral band. We also measured the distance between the center of the posterolateral band to the tibial posterolateral bone and the total length of the anteroposterior tibial insertion of the anterior cruciate ligament. RESULTS: In the femur, the distance from the center of the anteromedial band to the deep cartilage was 6.3 ± 1.4 mm, and 11.2 ± 2 mm to the ceiling. Also in the femur, the distance from the center of the posterolateral band to the deep cartilage was 9 ± 4 mm, to the superficial cartilage 7.6 ± 1.8 mm, and to the inferior cartilage 4.2 ± 0.9 mm. In the tibia, the distance from the anterior tibial bone edge to the anterior region of the anteromedial band was 11.9 ± 2.8 mm, to the center of the anteromedial band 18.8 ± 2.6 mm, and to the center of the posterolateral band 26.5 ± 2.3 mm. The distance from the center of the posterolateral band to the tibial posterior bone edge was 19.6 ± 4 mm and the total length of the anteroposterior tibial insertion of the anterior cruciate ligament was 19.4 ± 1.8 mm. CONCLUSION: The center of the tibial insertion of the anteromedial band is approximately 20mm distant from the anterior edge of the tibia, while the center of the posterolateral band is approximately 30mm. The distance between the center of the origin of the anteromedial band to the deep cartilage is 6mm, and to the posterior lateral 10mm.


Subject(s)
Humans , Anterior Cruciate Ligament/anatomy & histology , Knee/anatomy & histology , Anterior Cruciate Ligament/physiology , Cadaver , Knee/physiology , Range of Motion, Articular
SELECTION OF CITATIONS
SEARCH DETAIL